Add Signal
Function
A command that creates a new signal connection. It establishes communication connections with external devices.
Usage
-
Signal Type Selection: Choose the communication protocol to use
-
Modbus TCP/RTU
-
FOCAS
-
TCP Client/Server
-
Serial Communication
-
-
Setting Method Selection:
-
Default: Direct configuration
-
Module: Select pre-configured values from Device module
-
-
Connection Name Setting: Specify a unique connection name
-
No duplicates allowed
-
-
Communication Settings:
-
Default Mode: Direct input of device-specific detailed settings
-
Module Mode: Select pre-configured values
-
Precautions
-
Connection names must be unique within the project
-
Verify that IP addresses and ports are correct
-
Ensure the target device supports the selected protocol
Get Signal (Input/Read)
Function
A command that reads data from external devices.
Usage
-
Signal Type Selection: Choose the communication protocol to use
-
Digital I/O
-
Analog I/O
-
Industrial Ethernet
-
Modbus TCP/RTU
-
FOCAS
-
TCP Client/Server
-
Serial Communication
-
-
Type-specific Settings:
-
Digital I/O: Port number selection
-
Analog I/O: Port number selection, type selection
-
Industrial Ethernet: Data type, address type, address setting
-
Other Protocols: Connection name selection (connections created by Add Signal)
-
-
Variable Selection: Select variable to store the read data
Set Signal (Output/Write)
Function
A command that transmits (outputs) data to external devices.
Usage
-
Signal Type Selection: Choose the communication protocol to use
-
Digital I/O
-
Analog I/O
-
Industrial Ethernet
-
Modbus TCP/RTU
-
TCP Client/Server
-
Serial Communication
-
-
Type-specific Settings:
-
Digital I/O: Port number selection
-
Analog I/O: Port number selection, type selection
-
Industrial Ethernet: Data type, address setting
-
Other Protocols: Connection name selection (connections created by Add Signal)
-
-
Value Setting: Input the value to transmit
Delete Signal
Function
A command that deletes existing signal connections.
Usage
-
Connection Name Selection: Select the connection name to delete
Supported Protocols
|
Protocol |
Description |
Main Usage |
|---|---|---|
|
Digital I/O |
Digital Input/Output |
Switches, Relays |
|
Analog I/O |
Analog Input/Output |
Sensors, Actuators |
|
Ethernet/IP |
Industrial Ethernet |
Allen-Bradley PLC |
|
Modbus TCP |
Ethernet-based Modbus |
PLC, Industrial Equipment |
|
Modbus RTU |
Serial-based Modbus |
Sensors, Instruments |
|
TCP Client/Server |
General TCP Communication |
Custom Equipment |
|
Serial |
Serial Communication |
Legacy Equipment |
|
FOCAS |
FANUC CNC |
CNC Machines |
Troubleshooting
Common Issues
-
Connection Failure
-
Check network settings
-
Check firewall settings
-
Check equipment power status
-
-
Data Read/Write Failure
-
Check address range
-
Check data type matching
-
-
Performance Degradation
-
Adjust polling cycle
-
Remove unnecessary connections
-