set_force_factor()

Definition

set_force_factor(force_factor, time)

Features

In force control, This function sets the force factor based on the global coordinate (refer to set_ref_coord())

Caution

In non-FTS models (A0509, A0912, A0509F, A0912F, E0509), compliance control is only possible in the translation direction, and the control error may be large.

Parameters

Parameter Name

Data Type

Default Value

Description

force_factor

float[6]

[1.0, 1.0, 1.0, 1.0, 1.0, 1.0]

(Translation x, y, z), (Rotation x, y, z)

Range: 0.1 - 2.0

time

float

0

Force factor varying time [sec]

Range: 0 - 1.0

* Linear transition during the specified time

Caution

In the Non-FTS A & E model, the data type of the force_factor parameter can be either float[6] or float[3] (rotational parameter is automatically set to  the default value)

Note

  • When the force factor is set to the default value (1.0), it operates with the default damping value set according to the model.

  • Setting the force factor below 1.0 reduces the setting time to follow the target force value, but may increase vibration.

  • Setting the force factor above 1.0 may reduce vibration but increase the setting time to follow the target force value.

  • The force factor setting is applied only during force control. It is applied as a default value for compliance control.

  • This function is supported only for the M series. It cannot be used for A series and H series.

Warning

  • If the force factor is set to less than 1.0, the robot may vibrate depending on the contact surface. Please use it carefully.

Return

Value

Description

0

Success

Negative value

Error

Exception

Exception

Description

DR_Error (DR_ERROR_TYPE)

Parameter data type error occurred

DR_Error (DR_ERROR_VALUE)

Parameter value is invalid

DR_Error (DR_ERROR_RUNTIME)

C extension module error occurred

DR_Error (DR_ERROR_STOP)

Program terminated forcefully

Example

Python
# 1. Move to initial posj
q0 = posj(0.0, 0.0, 90.0, 0.0, 90.0, 0.0)
set_velj(30.0)
set_accj(60.0)
movej(q0)
 
# 2. Start force control (apply -20N force along Base–z direction)
k_d = [3000.0, 3000.0, 3000.0, 200.0, 200.0, 200.0]
task_compliance_ctrl(k_d)
force_desired = 20.0
f_d = [0.0, 0.0, -force_desired, 0.0, 0.0, 0.0]
f_dir = [0, 0, 1, 0, 0, 0]
d_f = [1.0, 1.0, 0.8, 1.0, 1.0, 1.0]
f_f = [1.0, 1.0, 1.2, 1.0, 1.0, 1.0]
set_desired_force(f_d, f_dir)
set_damping_factor(d_f)
set_force_factor(f_f)
wait(2.0)
release_force()
wait(0.5)
release_compliance_ctrl()