Definition
set_analog_output(ch, val)
Features
This function outputs the channel value corresponding to the controller analog output.
Parameters
|
Parameter Name |
Data Type |
Default Value |
Description |
|---|---|---|---|
|
ch |
int |
- |
|
|
val |
float |
- |
analog output value
|
Return
|
Value |
Description |
|---|---|
|
0 |
Success |
|
Negative value |
Failed |
Exception
|
Exception |
Description |
|---|---|
|
DR_Error (DR_ERROR_TYPE) |
Parameter data type error occurred |
|
DR_Error (DR_ERROR_VALUE) |
Parameter value is invalid |
|
DR_Error (DR_ERROR_RUNTIME) |
C extension module error occurred |
|
DR_Error (DR_ERROR_STOP) |
Program terminated forcefully |
Example
Python
set_mode_analog_output(ch=1, mod=DR_ANALOG_CURRENT) #out ch1=current mode
set_mode_analog_output(ch=2, mod=DR_ANALOG_VOLTAGE) #out ch1=voltage mode
set_analog_output(ch=1, val=5.2) # Outputs 5.2 mA to channel 1
set_analog_output(ch=2, val=10.0) # Outputs 10V to channel 2