Definition
set_eip_gpr_expand_output_register_float(address, val)
Features
It is used to export values to the Output Float General Purpose Register (Expand) area of the Industrial Ethernet(EtherNet/IP, PROFINET) Slave.
Parameters
|
Parameter Name |
Data Type |
Default Value |
Description |
|---|---|---|---|
|
address |
unsigned short |
- |
Address value of Output Float GPR (Expand) area in Industrial Ethernet Slave(0-49) |
|
val |
float |
- |
float value (4byte) |
Return
|
Value |
Description |
|---|---|
|
0 |
Success |
|
Negative value |
Failure |
Exception
|
Exception |
Description |
|---|---|
|
DR_Error (DR_ERROR_TYPE) |
Parameter data error occurred |
|
DR_Error (DR_ERROR_VALUE) |
Parameter value is invalid |
|
DR_Error (DR_ERROR_RUNTIME) |
C Extension module error occurred |
|
DR_Error (DR_ERROR_STOP) |
Program terminated forcefully |
Example
Python
set_eip_gpr_expand_output_register_float(0, 4.5)
set_eip_gpr_expand_output_register_float(23, 2.3)
Keyword
set_ / output / register / output_register / expand / register_float