Breadcrumbs

add_modbus_rtu_signal()

Definition

add_modbus_rtu_signal(slaveid=1, port=None, baudrate=115200, bytesize=DR_EIGHTBITS, parity=DR_PARITY_NONE, stopbits=DR_STOPBITS_ONE, name, reg_type, index)

Starting with version 3.5, the value parameter of the add_modbus_signal function has been removed. Programs that previously used this function may encounter an error pop-up.

Features

This function registers the ModbusRTU signal. The Modbus I/O must be set in the Teach Pendant I/O set-up menu. Use this command only for testing if it is difficult to use the Teach Pendant. The Modbus menu is disabled in the Teach Pendant if it is set using this command.

Parameters

Parameter Name

Data Type

Default Value

Description

slaveid

int

1

Slave ID of the ModbusRTU (0 or 1-247)

0 : Broadcase address

port

string

None

E.g.) “COM”, “COM_USB”, “/dev/ttyUSB0”

baudrate

int

115200

Baud rate

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

bytesize

int

8

Number of data bits

  • DR_EIGHTBITS: 8

parity

string

"N"

Parity checking

  • DR_PARITY_NONE: "N"

  • DR_PARITY_EVEN: "E"

  • DR_PARITY_ODD: "O"

stopbits

int

1

Number of stop bits

  • DR_STOPBITS_ONE =1

  • DR_STOPBITS_TWO = 2

name

string

-

Modbus signal name

reg_type

int

-

Modbus signal type

  • DR_DISCRETE_INPUT =DR_MODBUS_DIG_INPUT

  • DR_COIL =DR_MODBUS_DIG_OUTPUT

  • DR_INPUT_REGISTER =DR_MODBUS_REG_INPUT

  • DR_HOLDING_REGISTER =DR_MODBUS_REG_OUTPUT

index

int

-

Modbus signal index

Return

Value

Description

0

Success

Negative value

Failed

Exception

Exception

Description

DR_Error (DR_ERROR_TYPE)

Parameter data type error occurred

DR_Error (DR_ERROR_VALUE)

Parameter value is invalid

DR_Error (DR_ERROR_RUNTIME)

C extension module error occurred

DR_Error (DR_ERROR_STOP)

Program terminated forcefully

Example

Python
add_modbus_rtu_signal(slaveid=1, port=port_info, baudrate=115200, bytesize=DR_EIGHTBITS, parity=DR_PARITY_NONE, stopbits=DR_STOPBITS_ONE, name=’di1’, reg_type=DR_INPUT_REGISTER, index=0)
add_modbus_rtu_signal(slaveid=1, port=port_info, baudrate=115200, bytesize=DR_EIGHTBITS, parity=DR_PARITY_NONE, stopbits=DR_STOPBITS_ONE, name=’do1’, reg_type=DR_HOLDING_REGISTER, index=0)