app_weld_set_interface_eip_m2r_other()

Definition

app_weld_set_interface_eip_m2r_other(opt1=[0,0,0,0,0,0,0,0,0], opt2=[0,0,0,0,0,0,0,0,0], opt3=[0,0,0,0,0,0,0,0,0], opt4=[0,0,0,0,0,0,0,0,0], opt5=[0,0,0,0,0,0,0,0,0], opt6=[0,0,0,0,0,0,0,0,0], opt7=[0,0,0,0,0,0,0,0,0], ...)

Features

This sets the communication interface setting to use welders that support EtherNet/IP communication. Required functions other than basic setting items (app_weld_set_interface_eip_m2r_process(), app_weld_set_interface_eip_m2r_monitoring(), app_weld_set_interface_eip_m2r_other(), app_weld_set_interface_eip_r2m_condition()) in the communication data sent to the robot controller from the welder can be set with the corresponding command. Enter the setting values below along with details based on the communication signal data sheet of the corresponding welder.

Note

To ensure proper welding using an EtherNet/IP remote control welder, all of 8 interface commands must be set up.

app_weld_set_interface_eip_r2m_process(),

app_weld_set_interface_eip_r2m_mode(),

app_weld_set_interface_eip_r2m_test(),

app_weld_set_interface_eip_r2m_condition(),

app_weld_set_interface_eip_r2m_option(),

app_weld_set_interface_eip_m2r_process(),

app_weld_set_interface_eip_m2r_monitoring(),

app_weld_set_interface_eip_m2r_other()

Note

EIP communication settings must be set to Monitoring+GPR.

Parameters

Parameter Name

Data Type

Default Value

Description

opt1

Specification

opt2

Specification

opt3

Specification

opt4

Specification

opt5

Specification

opt6

Specification

opt7

Specification

opt8

Specification

opt9

Specification

opt10

Specification

The data type, default value and description are identical to the below

Parameter Name

Data Type

Default Value

Description


list(int[7])

0

Not Used: 0

Used: 1

0

Data Type (on/off: 0, Select: 1, Value: 2)

0

Data Digits (1: 0, 0.1: 1, 0.01: 2)

0

Communication Data Point (byte): 0~255

0

Communication Data Point (bit): 0~7

0

Data Size

1-bit(disable Low): 0

1-bit(disable High): 1

2-bit: 2

4-bit: 3

8-bit(byte): 4

15-bit: 5

16-bit(short): 6

32-bit(int): 7

0

Valid Data Size

Value (bit)

list(float[2])

0

Minimum Data Value

0

Maximum Data Value

Note

For examples of data (0~2) interface settings, refer to the app_weld_set_interface_eip_r2m_process() section.

Return

Value

Description

0

Success

Negative Value

Failure

Exception

Exception

Description

DR_Error (DR_ERROR_TYPE)

Parameter data error

DR_Error (DR_ERROR_VALUE)

Invalid parameter value

DR_Error (DR_ERROR_RUNTIME)

C Extension module error

DR_Error (DR_ERROR_STOP)

Program terminated forcibly

Example

Python
app_weld_set_interface_eip_m2r_other(opt1=[1,2,1,12,0,6,15,0.0,25.5], 
                                     opt2=[1,0,0,0,1,0,1,0,0], 
                                     opt3=[0,0,0,0,0,0,0,0,0], 
                                     opt4=[0,0,0,0,0,0,0,0,0], 
                                     opt5=[0,0,0,0,0,0,0,0,0], 
                                     opt6=[0,0,0,0,0,0,0,0,0], 
                                     opt7=[0,0,0,0,0,0,0,0,0], 
                                     opt8=[0,0,0,0,0,0,0,0,0], 
                                     opt9=[0,0,0,0,0,0,0,0,0], 
                                     opt10=[0,0,0,0,0,0,0,0,0])