Breadcrumbs

set_mode_analog_output()

Definition

set_mode_analog_output(ch, mod)

Features

This function sets the channel mode of the controller analog output.

Parameters

Parameter Name

Data Type

Default Value

Description

ch

int

-

  • 1 : channel 1

  • 2 : channel 2

mod

int

-

analog io mode

  • DR_ANALOG_CURRENT: Current mode

  • DR_ANALOG_VOLTAGE: Voltage mode

Return

Value

Description

0

Success

Negative value

Failed

Exception

Exception

Description

DR_Error (DR_ERROR_TYPE)

Parameter data type error occurred

DR_Error (DR_ERROR_VALUE)

Parameter value is invalid

DR_Error (DR_ERROR_RUNTIME)

C extension module error occurred

DR_Error (DR_ERROR_STOP)

Program terminated forcefully

Example

Python
# Sets analog_output channel 1 to the current mode.
set_mode_analog_output(ch=1, mod=DR_ANALOG_CURRENT) 

# Sets analog_output channel 2 to the voltage mode.