Definition
set_output_register_int(address, val)
Features
It is used to export values to the Output Int General Purpose Register area of the Industrial Ethernet(EtherNet/IP, PROFINET) Slave.
Parameters
|
Parameter Name |
Data Type |
Default Value |
Description |
|---|---|---|---|
|
address |
unsigned short |
- |
Address value of Output Int GPR area in Industrial Ethernet Slave(0-23) |
|
val |
int |
- |
int value (4byte) |
Return
|
Value |
Description |
|---|---|
|
0 |
Success |
|
Negative value |
Failure |
Exception
|
Exception |
Description |
|---|---|
|
DR_Error (DR_ERROR_TYPE) |
Parameter data error occurred |
|
DR_Error (DR_ERROR_VALUE) |
Parameter value is invalid |
|
DR_Error (DR_ERROR_RUNTIME) |
C Extension module error occurred |
|
DR_Error (DR_ERROR_STOP) |
Program terminated forcefully |
Example
Python
set_output _register_int (0, 0x00FF00FF)
set_output _register_int (23, 65535)