This structure contains analog welding interface configuration information.
-
_bModemember variable sets the analog welding interface mode. A value of 0 means stop, and a value of 1 means start. -
_tTargetVoltage,_tFeedingSpeed,_tWeldingVoltage, and_tWeldingCurrentmember variables areCONFIG_WELDING_DETAIL_INFOstructures that contain detailed configuration information for target voltage, feeding speed, welding voltage, and welding current, respectively. -
_iArcOnDO,_iGasOnDO,_iInchPDO, and_iInchNDOmember variables represent the DO numbers to be used for arc start, gas start, inch plus, and inch minus, respectively. -
_iBlowOutValuemember variable represents the blowout value.
|
BYTE# |
Member Variable |
DataType |
Value |
Descriptions |
|---|---|---|---|---|
|
0 |
|
|
0 or 1 |
Analog Welding Interface Mode (0: stop, 1:start) |
|
1 |
|
|
|
Target Voltage Configuration |
|
17 |
|
|
|
Target Speed Configuration |
|
33 |
|
|
|
Welding Voltage Configuration |
|
49 |
|
|
|
Welding Current Configuration |
|
65 |
|
|
0 ~ 16 |
Arc Starting DO number |
|
66 |
|
|
0 ~ 16 |
Gas Starting DO Number |
|
67 |
|
|
0 ~ 16 |
Inch Plus DO number |
|
68 |
|
|
0 ~ 16 |
Inch Minus DO number |
|
69 |
|
|
0 ~ 16 |
Blowout Value |