This structure contains information for adjusting welding settings.
-
_bRealTimeindicates whether real-time adjustment is enabled. A value of 0 means preset mode, and a value of 1 means real-time adjustment mode. -
_bResetFlagindicates the reset flag. A value of 0 means to maintain the current value, and a value of 1 means to reset to the set value. -
_fTargetVol,_fTargetCur, and_fTargetVelrepresent the target voltage, target current, and target speed, respectively. -
_fOffsetYand_fOffsetZrepresent the weaving Y offset and weaving Z offset, respectively. -
_fWidthRaterepresents the weaving width rate.
|
BYTE# |
Member Variable |
Data Type |
Value |
Description |
|---|---|---|---|---|
|
0 |
|
|
0 or 1 |
Real-time adjustment status (0: Preset, 1: Real-time) |
|
1 |
|
|
0 or 1 |
Reset Flag ( 0: Maintain Current Value, 1: Reset) |
|
2 |
|
|
|
Target Voltage |
|
6 |
|
|
|
Target Current |
|
10 |
|
|
|
Target Speed |
|
14 |
|
|
|
Weaving Y Offeset |
|
18 |
|
|
|
Weaving Z Offset |
|
22 |
|
|
|
Weaving Width Rate |