app_weld_set_interface_eip_r2m_condition(job_num=[0,0,0,0,0,0,0,0,0], synergic_id=[0,0,0,0,0,0,0,0,0], r_wire_feed_speed=[0,0,0,0,0,0,0,0,0], voltage_corret=[0,0,0,0,0,0,0,0.0,0.0], dynamic_correct=[0,0,0,0,0,0,0,0,0])

Features

This sets the communication interface setting to use welders that support EtherNet/IP communication. This sets the interface related to the welding condition setting in the communication data sent to the welder from the robot controller. Enter the setting values below along with details based on the communication signal data sheet of the corresponding welder.


Note

To ensure proper welding using an EtherNet/IP remote control welder, all of 8 interface commands must be set up.

app_weld_set_interface_eip_r2m_process(), app_weld_set_interface_eip_r2m_mode(), app_weld_set_interface_eip_r2m_test(), app_weld_set_interface_eip_r2m_condition(), app_weld_set_interface_eip_r2m_option(), app_weld_set_interface_eip_m2r_process(), app_weld_set_interface_eip_m2r_monitoring(), app_weld_set_interface_eip_m2r_other()

Parameter

Parameter Name

Data Type

Default Value

Description

job_num

Refer to the table below

Refer to the table below

JOB Number (specification for each welder)

synergic_id

SYNERGIC Number (specification for each welder)

r_wire_feed_speed

Wire Feeding Speed Correction (specification for each welder)

voltage_correct

Voltage Correction (specification for each welder)

dynamic_correct

Dynamic Correction (specification for each welder)

The data type, default value and description are identical to the below

Parameter Name

Data Type

Default Value

Description


list(int[7])

0

Not Used: 0

Used: 1

0

Data Type (on/off: 0, Select: 1, Value: 2)

0

Data Digits (1: 0, 0.1: 1, 0.01: 2)

0

Communication Data Point (byte): 1~255

0

Communication Data Point (bit): 1~255

0

Data Size

1-bit(disable Low): 0

1-bit(disable High): 1

2-bit: 2

4-bit: 3

8-bit(byte): 4

15-bit: 5

16-bit(short): 6

32-bit(int): 7

0

Valid Data Size

Value (bit)

list(float[2])

0

Minimum Data Value

0

Maximum Data Value

Note

For examples of data (0~2) interface settings, refer to the app_weld_set_interface_eip_r2m_process() section.

Return

ValueDescription

0

Success

Negative Value

Failure

Exception

ExceptionDescription

DR_Error (DR_ERROR_TYPE)

Parameter data error

DR_Error (DR_ERROR_VALUE)

Invalid parameter value

DR_Error (DR_ERROR_RUNTIME)

C Extension module error

DR_Error (DR_ERROR_STOP)

Program terminated forcibly

Example

PY
app_weld_set_interface_eip_r2m_condition(job_num=[1,1,0,3,0,4,8,0,255], synergic_id=[1,1,0,2,0,3,4,0,15], r_wire_feed_speed=[1,2,1,6,0,6,15,0.0,25.0], voltage_corret=[1,2,1,8,0,6,15,-10.0,10.0], dynamic_correct=[1,2,0,10,0,6,15,-40,40])

Related commands