app_weld_set_interface_eip_m2r_other(opt1=[0,0,0,0,0,0,0,0,0], opt2=[0,0,0,0,0,0,0,0,0], opt3=[0,0,0,0,0,0,0,0,0], opt4=[0,0,0,0,0,0,0,0,0], opt5=[0,0,0,0,0,0,0,0,0], opt6=[0,0,0,0,0,0,0,0,0], opt7=[0,0,0,0,0,0,0,0,0],...)

Features

This sets the communication interface setting to use welders that support EtherNet/IP communication. Required functions other than basic setting items (app_weld_set_interface_eip_m2r_process(), app_weld_set_interface_eip_m2r_monitoring(), app_weld_set_interface_eip_m2r_other(), app_weld_set_interface_eip_r2m_condition()) in the communication data sent to the robot controller from the welder can be set with the corresponding command. Enter the setting values below along with details based on the communication signal data sheet of the corresponding welder.


Note

To ensure proper welding using an EtherNet/IP remote control welder, all of 8 interface commands must be set up.

app_weld_set_interface_eip_r2m_process(), app_weld_set_interface_eip_r2m_mode(), app_weld_set_interface_eip_r2m_test(), app_weld_set_interface_eip_r2m_condition(), app_weld_set_interface_eip_r2m_option(), app_weld_set_interface_eip_m2r_process(), app_weld_set_interface_eip_m2r_monitoring(), app_weld_set_interface_eip_m2r_other()

Parameter

Parameter NameData TypeDefault ValueDescription

opt1

Specification



opt2

Specification



opt3

Specification



opt4

Specification



opt5

Specification



opt6

Specification



opt7

Specification



opt8

Specification



opt9

Specification



opt10

Specification

The data type, default value and description are identical to the below

Parameter Name

Data Type

Default Value

Description


list(int[7])

0

Not Used: 0

Used: 1

0

Data Type (on/off: 0, Select: 1, Value: 2)

0

Data Digits (1: 0, 0.1: 1, 0.01: 2)

0

Communication Data Point (byte): 1~255

0

Communication Data Point (bit): 1~255

0

Data Size

1-bit(disable Low): 0

1-bit(disable High): 1

2-bit: 2

4-bit: 3

8-bit(byte): 4

15-bit: 5

16-bit(short): 6

32-bit(int): 7

0

Valid Data Size

Value (bit)

list(float[2])

0

Minimum Data Value

0

Maximum Data Value

Note

For examples of data (0~2) interface settings, refer to the app_weld_set_interface_eip_r2m_process() section.

Return

ValueDescription

0

Success

Negative Value

Failure

Exception

ExceptionDescription

DR_Error (DR_ERROR_TYPE)

Parameter data error

DR_Error (DR_ERROR_VALUE)

Invalid parameter value

DR_Error (DR_ERROR_RUNTIME)

C Extension module error

DR_Error (DR_ERROR_STOP)

Program terminated forcibly

Example

PY
app_weld_set_interface_eip_m2r_other(opt1=[1,2,1,12,0,6,15,0.0,25.5], opt2=[1,0,0,0,1,0,1,0,0], opt3=[0,0,0,0,0,0,0,0,0], opt4=[0,0,0,0,0,0,0,0,0], opt5=[0,0,0,0,0,0,0,0,0], opt6=[0,0,0,0,0,0,0,0,0], opt7=[0,0,0,0,0,0,0,0,0], opt8=[0,0,0,0,0,0,0,0,0], opt9=[0,0,0,0,0,0,0,0,0], opt10=[0,0,0,0,0,0,0,0,0])

Related commands