app_weld_set_interface_eip_m2r_process(current_flow=[0,0,0,0,0,0,0,0,0], process_active=[0,0,0,0,0,0,0,0,0], main_current=[0,0,0,0,0,0,0,0,0], machine_ready=[0,0,0,0,0,0,0,0,0], comm_ready=[0,0,0,0,0,0,0,0,0])
Features
This sets the communication interface setting to use welders that support EtherNet/IP communication. The link signal interface between the controller and welder in the communication data sent to the welder from the robot controller can be set. Enter the setting values below along with details based on the communication signal data sheet of the corresponding welder.
Note
- To ensure proper welding using an EtherNet/IP remote control welder, all of 8 interface commands must be set up. app_weld_set_interface_eip_r2m_process(), app_weld_set_interface_eip_r2m_mode(), app_weld_set_interface_eip_r2m_test(), app_weld_set_interface_eip_r2m_condition(), app_weld_set_interface_eip_r2m_option(), app_weld_set_interface_eip_m2r_process(), app_weld_set_interface_eip_m2r_monitoring(), app_weld_set_interface_eip_m2r_other()
- Start robot motion links with the current_flow signal from the welder but is linked with the corresponding signal when the main_current item is set.
- End robot motion links with the current_flow signal from the welder but is linked with the corresponding signal when the process_active item is set.
Parameter
Parameter Name | Data Type | Default Value | Description |
---|---|---|---|
current_flow | Refer to the table below | Refer to the table below | Welding Current Generated (specification for each welder) |
process_active | Welding Process Activated (specification for each welder) | ||
main_current | Regular Welding Current Generated (specification for each welder) | ||
machine_ready | Welding Standby (specification for each welder) | ||
comm_ready | Communication Standby (specification for each welder) |
The data type, default value and description are identical to the below
Parameter Name | Data Type | Default Value | Description |
---|---|---|---|
list(int[7]) | 0 | Not Used: 0 Used: 1 | |
0 | Data Type (on/off: 0, Select: 1, Value: 2) | ||
0 | Data Digits (1: 0, 0.1: 1, 0.01: 2) | ||
0 | Communication Data Point (byte): 1~255 | ||
0 | Communication Data Point (bit): 1~255 | ||
0 | Data Size 1-bit(disable Low): 0 1-bit(disable High): 1 2-bit: 2 4-bit: 3 8-bit(byte): 4 15-bit: 5 16-bit(short): 6 32-bit(int): 7 | ||
0 | Valid Data Size Value (bit) | ||
list(float[2]) | 0 | Minimum Data Value | |
0 | Maximum Data Value |
Note
For examples of data (0~2) interface settings, refer to the app_weld_set_interface_eip_r2m_process() section.
Return
Value | Description |
---|---|
0 | Success |
Negative Value | Failure |
Exception
Exception | Description |
---|---|
DR_Error (DR_ERROR_TYPE) | Parameter data error |
DR_Error (DR_ERROR_VALUE) | Invalid parameter value |
DR_Error (DR_ERROR_RUNTIME) | C Extension module error |
DR_Error (DR_ERROR_STOP) | Program terminated forcibly |
Example
app_weld_set_interface_eip_m2r_process(current_flow=[1,0,0,0,0,0,1,0,0], process_active=[1,0,0,0,6,0,1,0,0], main_current=[1,0,0,0,5,0,1,0,0], machine_ready=[0,0,0,0,0,0,0,0,0], comm_ready=[0,0,0,0,0,0,0,0,0])
Related commands
- app_weld_set_interface_eip_r2m_process(welding_start=[0,0,0,0,0,0,0,0,0], robot_ready=[0,0,0,0,0,0,0,0,0], error_reset=[0,0,0,0,0,0,0,0,0])
- app_weld_set_interface_eip_r2m_mode(welding_mode=[0,0,0,0,0,0,0,0,0], s_2t=[0,0,0,0,0,0,0,0,0], pulse_mode=[0,0,0,0,0,0,0,0,0],wm_opt1=[0,0,0,0,0,0,0,0,0])
- (V2.11.0.1_temp-en_US) app_weld_set_interface_eip_r2m_test(gas_test=[0,0,0,0,0,0,0,0,0], inching_plus=[0,0,0,0,0,0,0,0,0], inching_minus=[0,0,0,0,0,0,0,0,0], blow_out_torch=[0,0,0,0,0,0,0,0,0], simulation=[0,0,0,0,0,0,0,0,0], ts_opt1=[0,0,0,0,0,0,0,0,0], ...)
- (2.11.2_temp-en_US) app_weld_set_interface_eip_r2m_condition(job_num=[0,0,0,0,0,0,0,0,0], synergic_id=[0,0,0,0,0,0,0,0,0], r_wire_feed_speed=[0,0,0,0,0,0,0,0,0], voltage_corret=[0,0,0,0,0,0,0,0.0,0.0], dynamic_correct=[0,0,0,0,0,0,0,0,0])
- (2.11.2_temp-en_US) app_weld_set_interface_eip_r2m_option(opt1=[0,0,0,0,0,0,0,0,0], opt2=[0,0,0,0,0,0,0,0,0], opt3=[0,0,0,0,0,0,0,0,0], opt4=[0,0,0,0,0,0,0,0,0], opt5=[0,0,0,0,0,0,0,0,0], opt6=[0,0,0,0,0,0,0,0,0],...)
- app_weld_set_interface_eip_m2r_process(current_flow=[0,0,0,0,0,0,0,0,0], process_active=[0,0,0,0,0,0,0,0,0], main_current=[0,0,0,0,0,0,0,0,0], machine_ready=[0,0,0,0,0,0,0,0,0], comm_ready=[0,0,0,0,0,0,0,0,0])
- app_weld_set_interface_eip_m2r_monitoring(welding_voltage=[0,0,0,0,0,0,0,0,0], welding_current=[0,0,0,0,0,0,0,0,0], wire_feed_speed=[0,0,0,0,0,0,0,0,0], wire_stick=[0,0,0,0,0,0,0,0,0], error=[0,0,0,0,0,0,0,0,0], ...)
- app_weld_set_interface_eip_m2r_other(opt1=[0,0,0,0,0,0,0,0,0], opt2=[0,0,0,0,0,0,0,0,0], opt3=[0,0,0,0,0,0,0,0,0], opt4=[0,0,0,0,0,0,0,0,0], opt5=[0,0,0,0,0,0,0,0,0], opt6=[0,0,0,0,0,0,0,0,0], opt7=[0,0,0,0,0,0,0,0,0],...)