Skip to main content
Skip table of contents

app_weld_set_interface_eip_m2r_monitoring(welding_voltage=[0,0,0,0,0,0,0,0,0], welding_current=[0,0,0,0,0,0,0,0,0], wire_feed_speed=[0,0,0,0,0,0,0,0,0], wire_stick=[0,0,0,0,0,0,0,0,0], error=[0,0,0,0,0,0,0,0,0], ...)

Features

This sets the communication interface setting to use welders that support EtherNet/IP communication. This sets the interface related to monitoring of the welding machine’s status setting in the communication data sent to the welder from the robot controller. Enter the setting values below along with details based on the communication signal data sheet of the corresponding welder.


Note

To ensure proper welding using an EtherNet/IP remote control welder, all of 8 interface commands must be set up.

app_weld_set_interface_eip_r2m_process(), app_weld_set_interface_eip_r2m_mode(), app_weld_set_interface_eip_r2m_test(), app_weld_set_interface_eip_r2m_condition(), app_weld_set_interface_eip_r2m_option(), app_weld_set_interface_eip_m2r_process(), app_weld_set_interface_eip_m2r_monitoring(), app_weld_set_interface_eip_m2r_other()

Parameter

Parameter Name

Data Type

Default Value

Description

welding_voltage

Refer to the table belowRefer to the table below





Actual Welding Voltage (specification for each welder)

welding_current

Actual Welding Current (specification for each welder)

wire_feed_speed

Actual Wire Feeding Speed (specification for each welder)

wire_stick

Check Wire Stick Status (specification for each welder)

error

Check Error Status (specification for each welder)

error_num

Check Error Number (specification for each welder)

The data type, default value and description are identical to the below

Parameter Name

Data Type

Default Value

Description


list(int[7])

0

Not Used: 0

Used: 1

0

Data Type (on/off: 0, Select: 1, Value: 2)

0

Data Digits (1: 0, 0.1: 1, 0.01: 2)

0

Communication Data Point (byte): 1~255

0

Communication Data Point (bit): 1~255

0

Data Size

1-bit(disable Low): 0

1-bit(disable High): 1

2-bit: 2

4-bit: 3

8-bit(byte): 4

15-bit: 5

16-bit(short): 6

32-bit(int): 7

0

Valid Data Size

Value (bit)

list(float[2])

0

Minimum Data Value

0

Maximum Data Value

Note

For examples of data (0~2) interface settings, refer to the app_weld_set_interface_eip_r2m_process() section.

Return

Value
Description

0

Success

Negative Value

Failure

Exception

Exception
Description

DR_Error (DR_ERROR_TYPE)

Parameter data error

DR_Error (DR_ERROR_VALUE)

Invalid parameter value

DR_Error (DR_ERROR_RUNTIME)

C Extension module error

DR_Error (DR_ERROR_STOP)

Program terminated forcibly

Example

PY
app_weld_set_interface_eip_m2r_monitoring(welding_voltage=[0,0,0,0,0,0,0,0,0], welding_current=[0,0,0,0,0,0,0,0,0], wire_feed_speed=[0,0,0,0,0,0,0,0,0], wire_stick=[0,0,0,0,0,0,0,0,0], error=[0,0,0,0,0,0,0,0,0], error_num=[0,0,0,0,0,0,0,0,0])

Related commands

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.