1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish
1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish

CDRFLEx.set_modbus_output

Features

This is a function for outputting a signal at the modbus I/O contact point in the robot controller.

Parameter

Parameter Name

Data Type

Default Value

Description

strSymbol

string

-

Modbus name

nValue

unsigned short

-

  • In the case of Modbus digital I/O: 0 or 1

  • In the case of Modbus analog: Data

Return

Value

Description

0

Error

1

Success

Example

C++
//When the Modbus digital I/O is connected and the signal is registered as “di1” and “do1,”  
drfl.set_modbus_output("do1",1);
drfl.set_modbus_output("do2",0);