1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish
1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish

CDRFLEx.get_analog_input

Features

This is a function for checking a signal at the analog contact point mounted on the control box in the robot controller.

Parameter

Parameter Name

Data Type

Default Value

Description

eGpioIdex

enum.GPIO_CTRLBOX_ANALOG_INDEX_

-

Refer to the Definition of Constant and Enumeration Type

Return

Value

Description

Analog signal input

In the case of current mode: 4.0~20.0 [mA]

In the case of voltage mode: 0~10.0 [V]

Example

C++
// Sets the analog No. 1 input contact point on the control box to current mode. 
drfl.set_mode_analog_output(GPIO_CTRLBOX_ANALOG_INDEX_1, GPIO_ANALOG_TYPE_CURRENT);

// Checks the current value on the analog No. 1 input contact point on the control box.
float fCurrent = drfl.get_analog_input(GPIO_CTRLBOX_ANALOG_INDEX_1);