CDRFLEx.add_modbus_signal

Features

This is a function for using the Modbus I/O signal by registering it in advance. The modbus I/O signal registered using this function should be reset after rebooting, as it is stored in the memory. However, if it is registered in the T/P application, it can be reused, as it is added in the initialization process.

Parameter

Parameter Name

Data Type

Default Value

Description

strSymbol

string

-

modbus signal Name

strIpAddress

string

-

modbus module ip address

nPort

unsigned short

-

modbus module port

eRegType

enum

-

Refer to the Definition of Constant and Enumeration Type

iRegIndex

unsigned short

-

Index of Modbus signal

nRegValue

unsigned short

0

Output value when type is MODBUS_REGISTER_TYPE_COILS or MODBUS_REGISTER_TYPE_HOLDING_REGISTER (ignored in other cases)

Return

Value

Description

0

Error

1

Success

Example

C++
/*
Example of connecting Modbus IO and allocating contact point 
Modbus IO IP: 192.168.127.254
input 2 points: “di1”,”di2”
*/

// set <modbus> input : “di1”, “di2” 
drfl.add_modbus_signal("di1", "192.168.127.254" , 502, MODBUS_REGISTER_TYPE_DISCRETE_INPUTS, 0, 0);