Application Recovery Mode Screen

If a software error is detected during robot booting, the system enters Application Recovery Mode. This screen offers functions to preserve and restore application data. This screen is only available in English.

Using Application Recovery Mode Functions

No.ItemDescription

1

Robot Serial Number

This displays the serial number of the connected robot.

2

View Error Log

This displays the log of errors that triggered recovery mode.

3

Export System Log

This executes a function to extract the system log. The log from 2 days prior to the present day is extracted.

4

Database Backup

This executes a function to back up the database of the connected robot. Data backed up using this function can only be restored with the Restore Database function on this screen.

5

Reset Database

This executes a function to reset the database of the connected robot to its default state.

6

Restore Database

This restores the database using the file created with the Database Backup function on this screen.

7

Delete 3rd Party Workcell Item

This deletes 3rd party Workcell Items installed via 워크셀 & Skill 설치 및 제거

8

Restore System

This restores the application to a specific version. It works the same as System Restore function.

9

Unified Update

If the update fails, the system can be re-installed using the Unified Update function.

10

Restart

This restarts the controller.