Breadcrumbs

Connect power to controller

Mandatory EASY 1 min

To supply power to the controller, connect the power cable of the control box to a standard IEC power outlet.

  • After connecting the power cable, make sure that the robot is properly grounded (electrical ground connection).

  • Establish a common ground for all equipment in the system with unused bolts related to the ground symbol inside the controller. The ground conductor must satisfy the maximum current rating of the system.

  • For more information, refer to Connect Power to Controller.

Scroll conditional content 1m/hseries Scroll conditional content 2aseries Scroll conditional content 3eseries Scroll conditional content hidecontents Scroll conditional content tet

The power supply must satisfy minimum requirements such as grounding and circuit breakers. The electrical specifications of the included AC controller are as follows:

Parameter

Specifications

Input Voltage

100 – 240 VAC

Input Power Fuse (@100-240V)

15 A

Input Frequency

47 – 63 Hz


Refer to the following appendix for optional controller information.