CDRFLEx.set_velx_rt

Features

Set the global task velocity limit value used in the servo motion of real-time external control.

Parameter

Parameter Name

Data Type

Default Value

Description

fTransVel

float

-

Task Linear Velocity Limit [mm/s]

fRotationVel

float

-

Task Rotational Velocity Limit [deg/s], if None Value(-10000) entered, auto-calculated by Task Linear Velocity Limit


Note
  • If the velocity while moving using the servo motion function is greater than the global velocity limit, Info is generated.

Return

Value

Description

0

Error

1

Success

Example

C++
float vel[6] = {100, 100, 100, 100, 100, 100};
Drfl.set_velx_rt(vel);