Setting Analog I/O Terminal (TBAIO)


To ensure maximum input accuracy, observe the following:

  • Use shielded or twisted pair cables.

  • Connect the cable shield to the ground terminal inside the controller.


The electrical specifications of the analog I/O terminal are as follows:







-



4 - 20 mA





12 bit




0 - 10 V



-



1M ohm



12 bit




-



4 - 20 mA



50M ohm



16 bit




0 - 10 V



-



1 ohm



16 bit




  • Depending on the output signal (voltage/current) of the device, it is necessary to set the controller analog input as “Voltage” or “Current” on the teach pendant.

image2021-11-25_15-7-32.png



  • Depending on the input signal (voltage/current) of the device, it is necessary to set the controller analog output as “Voltage” or “Current” on the teach pendant.

image2021-11-25_15-11-56.png