Breadcrumbs

Measurement Poses and Conditions

Joint 1 measurement is performed with the rotating axis perpendicular to the ground and during horizontal movement.

Joint 2 and Joint 3 measurements are performed with the rotating axis parallel to the ground and when the robot is stopped in a downward movement vertical to the ground.

The measurements are the result of the worst case. Measurement may vary according to circumstances


The pose for 33%, 66%, and 100% of extension

Joint 1

Joint 2

Joint 3

100% extension

Stop category 0

image2023-5-16_19-16-17.png

image2023-5-16_19-16-17.png

image2023-5-16_19-17-12.png

33% extension

Stop category 1

image2023-5-16_19-17-51.png

image2023-5-16_19-17-51.png

-

66% extension

Stop category 1

image2023-5-16_19-19-13.png

image2023-5-16_19-19-18.png

-

100% extension

Stop category 1

image2023-5-16_19-20-25.png

image2023-5-16_19-20-25.png

image2023-5-16_19-20-54.png

The pose when the stop is initiated and the measured angle ( image2021-11-15_11-41-21.png )


Pose when the stop is initiated

Measured Angle

Joint1


image2023-5-16_19-21-26.png

No slip, image2021-11-15_11-8-31.png

Joint2

image2023-5-16_19-21-56.png

image2023-5-16_19-22-25.png

Joint3

image2023-5-16_19-23-23.png


image2023-5-16_19-23-53.png