1.33 1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish
1.33 1.32 1.31 1.30 1.29 1.28 1.20 Korean English Chinese Czech Dutch French German Hungarian Italian Japanese Polish Portuguese Spanish

struct.MONITORING_CTRLIO_EX2

This is structure information for checking I/O current state information installed in the control box of the robot controller, and is composed of the following fields.

BYTE#

Field Name

Data Type

Value

Remarks

0

I/O Information(#1)

-

-

Information on I/O Digital Input signal

48

I/O Information(#2)

-


Information on I/O Digital Output signal

90

I/O Information(#3)

-

-

Information on Encorder Data signal

102

Reserved Space

-

-

24 bytes Reserved Space


I/O Information (#1) consists of I / O input information attached to Safety B'd in the control box as follows.

BYTE#

Field Name

Data Type

Value

Remarks

0

Digital signal

uchar

0x00~0x01

Information on On/Off of 32 Digitals

32

Analog signal

float

-

Two Analogs

Numeric Information

40

Switch signal

uchar

0x00~0x01

Information on On/Off of Three Switches

43

Safety signal

uchar

0x00~0x01

Information on On/Off of Two Safeties

46

Analog mode

uchar

0x00~0x01

Two Analogs

Numeric Information

  • Switch signal information Three switch status information attached to the control box and T / P, such as a direct teaching button, and the safety signal is input information of two safety emergency input signals and two protective-stop signals attached to the control box.


I / O Information (# 2) consists of I / O output information attached to Safety B'd in the control box.

BYTE#

Field Name

Data Type

Value

Remarks

0

Digital signal

uchar

0x00~0x01

Information on On/Off of 32 Digitals

32

Analog signal

float

-

Two Analogs

Numeric Information

40

Analog mode

uchar

0x00~0x01

Two Analogs mode

Numeric Information


I / O Information (# 3) consists of Encorder data information attached to Safety B'd in the control box as follows.

BYTE#

Field Name

Data Type

Value

Remarks

0

Strobe signal

uchar

0x00~0x01

Information on On/Off of 2 Encorder

2

Raw data

uint

-

Two Encorder Numeric Information

10

Reset signal

uchar

0x00~0x01

Information on reset of 2 Encorder

  • The following input / output information is provided for the small model in the Reserved Space.

BYTE#

Field Name

Data Type

Value

Remarks

0

Digital input signal of process button

uchar

0x00~0x01

4 Digital On/Off Information