Setting Analog I/O Terminal (TBAIO)

To ensure maximum input accuracy, observe the following:

  • Use shielded or twisted pair cables.

  • Connect the cable shield to the ground terminal inside the controller.


The electrical specifications of the analog I/O terminal are as follows:

-

4 - 20 mA


12 bit

0 - 10 V

-

1M ohm

12 bit

-

4 - 20 mA

50M ohm

16 bit

0 - 10 V

-

1 ohm

16 bit

  • Depending on the output signal (voltage/current) of the device, it is necessary to set the controller analog input as “Voltage” or “Current” on the teach pendant.

  • Depending on the input signal (voltage/current) of the device, it is necessary to set the controller analog output as “Voltage” or “Current” on the teach pendant.