Tool Weight

The weight of the tool installed on the flange can be set by adding a tool weight Workcell Item. The Tool Weight can be set in Robot Parameters > Tool Settings > Tool Weight.

  • The tool weight can be measured using the auto measure function.
  • It is recommended to add tool weight as Workcell Items for each tool with a workpiece. If the workpiece weight is too heavy, the robot may recognize the weight of the workpiece as external force. It is because the robot determines this external force as a collision and stops.
  • When creating a task, change the weight Workcell Item according to the process to change the tool weight. For example, it is possible to configure a task to select the standard tool weight Workcell Item before picking up a workpiece, and select the tool weight Workcell Item with the workpiece after picking up a workpiece.


The activated tool weight Item can be set as the standard tool weight by pressing the set tool icon (

) on the top of the teach pendant.

  • Set of the tool setting is the same as the set of Other Commands. Set command can be used when changing the Tool Weight while a task is being performed. For more information, refer to Task Editor Module.


Note

  • Up to fifty different tool weights can be registered.



ItemDescription
1Lock Toggle ButtonUsed to lock the set value. The safety password is required for modifying the set value.
2AddingThis button allows you to add a new Tool Weight.
3DeletingThis button allows you to delete a Tool Weight.
4Tool Weight ListA list of the configured Tool Weights
5Tool Weight NameThis is where you can enter a name for the Tool Weight.
6Auto Measure MotionThis button allows you to run the automatic measurement.
7Automatic MeasurementThis button allows you to select an option and run an automatic measurement for it.
8Motion SelectionYou can select the desired Motion from the options.
9Selection of the Use of Weight

You can choose whether to use weight.

This selection box is disabled for E Series or A Series without FPT sensors.

10Weight InputThis is where you can enter the desired weight.
11Selection of the Use of Center of Gravity CXThe use of the center of gravity CX can be selected.
12CX InputCX can be entered.
13Selection of the Use of Center of Gravity CYThe use of the center of gravity CY can be selected.
14CY InputCY can be entered.
15Selection of the Use of Center of Gravity CZThe use of the center of gravity CZ can be selected.
16CZ InputCZ can be entered.
17Whether to Use InertiaThis checkbox allows you to choose whether to use inertia.
18lxx InputAn LXX entry for inertia can be entered.
19lyy InputAn lyy entry for inertia can be entered.
20lzz InputAn lzz entry for inertia can be entered.
21lxy InputAn lxy entry for inertia can be entered.
22lyz InputAn lyz entry for inertia can be entered.
23lzx InputAn lzx entry for inertia can be entered.
24SaveThis button allows you to save the setting values.