Skip to main content
Skip table of contents

Flange I/O

The end flange cover of the robot has one M8 spec 8-pin connector, and refer to the figure below for the location and shape.

The connector supplies power and control signals necessary to operate the gripper or sensors embedded within specific robot tools. The following are sample industrial cables (equivalent cables can be used):

  • Phoenix contact 1404178, male (Straight)
  • Phoenix contact 1404182, male (Right Angle)

The pin map of each connector is as follows:

Schematic Diagram





The I/O functions provided through X1 connector are different from each other, and refer to the table below for detailed I/O settings.

X1 Setting (Digital I/O, RS 485)


No

Signal

1

Digital Input 1

2

Digital Output 1

3

Digital Output 2

4

RS485 A

5

+24V

6

RS485 B

7

Digital Input 2

8

GND

Caution

  • Configure tools and grippers after checking I/O configuration based on production date (robot label mfg date).
  • You can find it on Doosan Robotlab.(https://robotlab .doosanrobotics.com)
  • If you run robot tools ignoring I/O configuration, the product can be damaged permanently.


Internal power of the flange I/O is set to 24V, and refer to the table below for detailed power specifications during I/O connection.

Parameter

Min

Typ

Max

Unit

Supply voltage

-

24

-

V

Supply current

-

2

3

A

Digital output

-

2

-

EA

Digital input

-

2

-

EA

The setting has been charged as follows since April 11, 2024

X1 Setting

No

Signal

1

Digital Input 1

2

Digital Output 1

3

Digital Output 2

4

Analog Input 1 / RS-485 +

5

+24V / +12V / 0V (off)

6

Analog Input 2 / RS-485 -

7

Digital Input 2

8

GND

I/O functions description

typeDescription
PowerSet the internal power supply to 0V (default), 12V or 24V
Digital Outputset to either PNP (Source Type, default) or NPN (Sink Type)
Digital InputPNP (Source Type, default)
Analog Input

set to either Voltage (0-10V) or Current (4-20mA, default)

RS-485Max 1M baud rate

Set the internal power supply to 0V, 12V or 24V.

The electrical specifications are shown below:

ParameterMinTypMaxUnit
Supply voltage (12V mode)11.41212.6V
Supply voltage (24V mode)22.82425.2V
Supply current--1.5A

Warning

  • Set up the tool and gripper so that they do not cause any hazards when power is cut off.
    (e.g., workpiece falling from the tool)
  • The No. 5 terminal of each connector outputs 24V at all times while power is supplied to the robot, so make sure to cut the power supply to the robot when setting up the tool and gripper.
JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.