Skip to main content
Skip table of contents

struct.GET_WELDING_SETTING_RESPONSE

The structure contains the respons of welding configuration information.

  • _bVirtualMode indicates whether the virtual welding mode is enabled.

  • _fTargetVol, _fTargetCur, and _fTargetVel represent the target voltage, target current, and target speed respectively.

  • _fTargetMinVel, and _fTargetMaxVel represent the minimum target speed and maximum target speed, respectively.

  • _tDetail is a structure that contains detailed welding configuration information.

    • _fRs, _fTss, _fTas, _fTwc, _fRf, _fTaf, and _fTsf represent the start rate, shieldinggas release time, start current time, welding condition change time, end rate, end current time, and end shielding gas release time, respectively.

BYTE#

Member Variable

Data Type

Value

Description

0

_bVirtualMode

unsigned char

0 or 1

whether the virtual welding mode is enabled. (0: deactive, 1: active)

1

_fTargetVol

float

 

Target Voltage

5

_fTargetCur

float

 

Target Current

9

_fTargetVel

float

 

Target Speed

13

_fTargetMinVel

float

 

Target Minumum Speed

17

_fTargetMaxVel

float

 

Target Maximum Speed

21

_tDetail._fRs

float

 

Start Rate

25

_tDetail._fTss

float

 

Shielding Release time

29

_tDetail._fTas

float

 

Start current time

33

_tDetail._fTwc

float

 

Welding condition change time

37

_tDetail._fRf

float

 

End rate

41

_tDetail._fTaf

float

 

End current time

45

_tDetail._fTsf

float

 

End shielding gas release time

JavaScript errors detected