struct.CONFIG_WELDING_INTERFACE
This structure contains configuration information for the welding interface.
_bEnableindicates whether the welding interface is enabled._tChOutis an array ofWELDING_CHANNELstructures that contains configuration information for the welding output channels (voltage, current)._tChInis an array ofWELDING_CHANNELstructures that contains configuration information for the welding input channels (voltage, current)._iArcOnDO,_iGasOnDO,_iInchPDO, and_iInchNDOrepresent the DO numbers used for arc start, gas start, inch plus, and inch minus, respectively.
BYTE# | Member Variable | Data Type | Value | Description |
|---|---|---|---|---|
0 |
|
| 0 or 1 | Whether the welding interface is enabled ( 0: disabled, 1: activate) |
1 |
|
| Output channel setting (Voltage, Current) | The welding output channels (voltage, current). |
19 |
|
| Input channel setting (Voltage, Current) | The welding input channels (voltage, current). |
37 |
|
| 0 ~ 15 | Arc starting DO number |
38 |
|
| 0 ~ 15 | Gas starting DO number |
39 |
|
| 0 ~ 15 | Inching plus DO number |
40 |
|
| 0 ~ 15 | Inching minus DO number |