struct.CONFIG_WELD_SETTING
The structure contains welding configuration information.
_bVirtualModeindicates whether the virtual welding mode is enabled._fTargetVol,_fTargetCur, and_fTargetVelrepresent the target voltage, target current, and target speed respectively._fTargetMinVel, and_fTargetMaxVelrepresent the minimum target speed and maximum target speed, respectively._tDetailis a structure that contains detailed welding configuration information._fRs,_fTss,_fTas,_fTwc,_fRf,_fTaf, and_fTsfrepresent the start rate, shieldinggas release time, start current time, welding condition change time, end rate, end current time, and end shielding gas release time, respectively.
BYTE# | Member Variable | Data Type | Value | Description |
|---|---|---|---|---|
0 |
|
| 0 or 1 | whether the virtual welding mode is enabled. (0: deactive, 1: active) |
1 |
|
| Target Voltage | |
5 |
|
| Target Current | |
9 |
|
| Target Speed | |
13 |
|
| Target Minumum Speed | |
17 |
|
| Target Maximum Speed | |
21 |
|
| Start Rate | |
25 |
|
| Shielding Release time | |
29 |
|
| Start current time | |
33 |
|
| Welding condition change time | |
37 |
|
| End rate | |
41 |
|
| End current time | |
45 |
|
| End shielding gas release time |