struct.CONFIG_ANALOG_WELDING_SETTING
This structure contains analog welding configuration information.
The
_iVirtualWeldingmember variable sets the virtual welding mode. A value of 0 means actual welding, and a value of 1 means virtual welding.The
_fTargetVoltage,_fTargetCurrent, and_fTargetVelmember variables set the target voltage, target current, and target speed, respectively.The
_fMinVeland_fMaxVelmember variables set the minimum speed and maximum speed, respectively.The
_tDetailmember variable is a structure that contains detailed welding configuration information.The
_fRs,_fTss,_fTas,_fTwc,_fRf,_fTaf, and_fTsfvariables represent the start rate, shielding gas release time, start current time, welding condition change time, end rate, end current time, and end shielding gas release time, respectively.The
_fStartVoltageand_fEndVoltagevariables represent the start voltage condition and end voltage condition, respectively.The
_fTargetFeedingSpeedmember variable sets the target feeding speed.
BYTE# | Member Variable | Data Type | Value | Description |
|---|---|---|---|---|
0 |
|
| 0 or 1 | 0: Real Welding 1: Virtual WElding |
1 |
|
| Target Voltage | |
5 |
|
| Target Current | |
9 |
|
| Target Speed(mm/sec) | |
13 |
|
| Minimum Speed | |
17 |
|
| Maximum Speed | |
21 |
|
| Start Rate | |
25 |
|
| Shielding Gas Release time(sec) | |
29 |
|
| Start Current Time (sec) | |
33 |
|
| Welding Condition changed time(sec) | |
37 |
|
| Terminate Ratio | |
41 |
|
| Terminate Current Time (sec) | |
45 |
|
| Terminated shielding Gas Release time(sec) | |
49 |
|
| Start Voltage Condition | |
53 |
|
| Terminate Voltage Condition | |
57 |
|
| Target Feeding Speed |