Skip to main content
Skip table of contents

struct.ADJUST_WELDING_SETTING

This structure contains information for adjusting welding settings.

  • _bRealTime indicates whether real-time adjustment is enabled. A value of 0 means preset mode, and a value of 1 means real-time adjustment mode.

  • _bResetFlag indicates the reset flag. A value of 0 means to maintain the current value, and a value of 1 means to reset to the set value.

  • _fTargetVol, _fTargetCur, and _fTargetVel represent the target voltage, target current, and target speed, respectively.

  • _fOffsetY and _fOffsetZ represent the weaving Y offset and weaving Z offset, respectively.

  • _fWidthRate represents the weaving width rate.

BYTE#

Member Variable

Data Type

Value

Description

0

_bRealTime

unsigned char

0 or 1

Real-time adjustment status (0: Preset, 1: Real-time)

1

_bResetFlag

unsigned char

0 or 1

Reset Flag ( 0: Maintain Current Value, 1: Reset)

2

_fTargetVol

float

Target Voltage

6

_fTargetCur

float

Target Current

10

_fTargetVel

float

Target Speed

14

_fOffsetY

float

Weaving Y Offeset

18

_fOffsetZ

float

Weaving Z Offset

22

_fWidthRate

float

Weaving Width Rate