app_weld_set_interface_eip_r2m_option
Features
This function configures the communication interface for using a welder that supports EtherNet/IP communication. It allows you to set up additional functions required beyond the default settings provided by the following commands:
app_weld_set_interface_eip_r2m_process()app_weld_set_interface_eip_r2m_mode()app_weld_set_interface_eip_r2m_test()app_weld_set_interface_eip_r2m_condition()
This configuration involves communication data that is sent from the robot controller to the welder. Refer to the communication signal datasheet of the corresponding welder for details related to the settings below.
Note:
To properly use the welding function with an EtherNet/IP communication-capable welder, all 8 types of interface setting commands must be configured:
app_weld_set_interface_eip_r2m_process()app_weld_set_interface_eip_r2m_mode()app_weld_set_interface_eip_r2m_test()app_weld_set_interface_eip_r2m_condition()app_weld_set_interface_eip_r2m_option()app_weld_set_interface_eip_m2r_process()app_weld_set_interface_eip_m2r_monitoring()app_weld_set_interface_eip_m2r_other()
Arguments
Argument Name | Data Type | Default Value | Description |
|---|---|---|---|
|
| None | Digital welding interface option settings structure |
The data type, default value, and description of the arguments within the structure are the same as below:
Argument Name | Data Type | Default Value | Description |
|---|---|---|---|
| unsigned char | None | Unused: 0 <br> Used: 1 |
| unsigned char | None | Data type (on/off: 0, selection: 1, value: 2) |
| unsigned char | None | Data digit (1: 0, 0.1: 1, 0.01: 2) |
| float | None | Minimum data value |
| float | None | Maximum data value |
| unsigned char | None | Communication data location (byte): 1~255 |
| unsigned char | None | Communication data location (bit): 1~255 |
| unsigned char | None | Data size <br> 1-bit (disable Low): 0 <br> 1-bit (disable High): 1 <br> 2-bit: 2 <br> 4-bit: 3 <br> 8-bit (byte): 4 <br> 15-bit: 5 <br> 16-bit (short): 6 <br> 32-bit (int): 7 |
| unsigned char | None | Effective data size <br> Value (bit) |
Return
Value | Description |
|---|---|
0 | Error |
1 | Success |
Example
CODE
|